Two changes have been made during the changeover between the old and new tank.
1. You will notice the green coating on the outside. The new tank is PTFE-coated.
These properties prevent a (total) loss of equipment if PUR-/ POR adhesive leaks. Adhesive residues can now be removed using a wooden stick. The cartridge can even be removed when the adhesive has set!
Hint: If even more adhesive has leaked, pull the plastic cap off the nozzle module. Then unfix the 2 screws on the nozzle module. These can then be removed. Loosen the cartridge which needs removing from the tank using light hammer taps on the visible cartridge opening.
2. Side opening on bottom of tank no longer needed.
In the old tank housings there was an outlet for spray air on the side. This was required for space reasons at the time. This tank version was fitted to spray and bead equipment. If lots of adhesive leaked it drained out through this opening in the housing in the worst case, clogged the housing and reacted there. This resulted in total loss of the equipment.Now the line version is fitted with a new tank without a hole and adhesive can no longer run out of the housing.
Left: old version with side opening, right: new version